Application
data transmission cable, control and connecting cable predominantly for transmission of
analog and digital signals in process controlled facilities in measurement and control
technology for lossless transmission of data and signals. For fixed laying and flexible
applications with undefined cable routing and without tensile stress. Suitable for use in
dry and humid rooms. Outdoor use only with UV-protection, no laying underground.
Special Features
• twisted pairs
• largely resistant to acids, bases and specified types of oil
• free from lacquer damaging substances and silicone (during production)
• recommended for EMC-applications
Structure & Specifications
conductor material:bare copper strand
conductor class: acc. to IEC 60228 cl. 5; exception: 0,34 mm², stranded
(7 x 0,25 mm)
core insulation: PVC
core identification: acc. to DIN 47100 different colours
stranding: 2 cores twisted to a pair; pairs stranded in layers
protection against contact: plastic foil
shield: copper braid tinned; coverage approx. 85%
outer sheath: PVC
sheath colour: grey, RAL 7032
rated voltage: 250 V; peak-voltage on 0,14 mm²: 350 V; > 0,14 mm²:
500 V
testing voltage: on 0,14 mm² core/core: 2kV; core/shield: 1,2kV > 0,14
mm²: core/core: 2kV; core/shield: 1,5kV
conductor resistance: acc. to IEC 60228 cl. 5
insulation resistance: min. 20 MΩ x km
current carrying capacity: acc. to DIN VDE, see Technical Guidelines
capacity: core/core ca. 120 nF/km; core/shield ca. 160 nF/km
min. bending radius fixed: up to 12 mm Ø: 5 x d; up to 20 mm Ø: 7,5 x d; > 20 mm
Ø: 10 x d
min. bending radius moved: up to 12 mm Ø: 10 x d; up to 20 mm Ø: 15 x d; > 20 mm
Ø: 20 x d
operat. temp. fixed min/max: -30 °C / +80 °C
operat. temp. moved min/max: -5 °C / +70 °C
burning behavior: self-extinguishing & flame-retardant acc.to IEC 60332-1
standard: similar to DIN VDE 0812