Home >> Products >> Optical cable

OFC GYBFY 4C G.652D PE

indoor/ outdoor GYFXTBY Flat Drop Cable FTTH Dry core Cable G.652D or G.657A1 6F /6core fiber optic cable
GYFBZY G.657A2 0.4mm Steel Wire Strength Member 2 Core Outdoor Fiber Optic Cable PE Jacket Optic Cable
OFC GYFXTBY Flat Single Core Optical Cable 2 12 Core Fiber Optic Cable Ftth Drop Cable
  1. Cable Cross-section

     

     

    Loose tube Optical fiber Filling gel FRP rod PE sheath

  2. SUK Cable Identification

      Cable Drop Plano OVAL  4 Hilos ,6 Hilos , 8 Hilos FTR 2mm

    Multitoma PDU 1U 19″ de Aluminio 4 tomas
    Sheath marking

    1. OFC GYBFY 4C G.652D PE : Cable type & size

      *The marking is printed every 1 meter

       

    2. Fiber color code

      No.

      1

      2

      3

      4

      Color

      Blue

      Orange

      Green

      Brown

       

  3. Cable Structure & Parameter

     

    Fiber count

    Loose tube dia.

    FRP rod dia.

    Sheath thickness

    (Nom.*)

    Overall Dimension (Nom.**)

    Weight (Approx.)

    mm

    mm

    mm

    mm

    kg/km

    4

    2.0

    2.0

    1.0

    4.0*8.0

    33

     

    • The nominal sheath thickness may have a tolerance with 0.2mm.

    • * The nominal overall dimension may have a tolerance with 0.4mm.

  4. Performance of Cabled Optical Fiber

    The performance of cabled optical fiber (ITU-T Rec. G.652D)

    Items

    Specification

    Attenuation coefficient

    @ 1310 nm

    @ 1550 nm

     

     0.35 dB/km

     0.21 dB/km

    Cable cut-off wavelength

     1260 nm

    Zero-dispersion wavelength

    1300 to 1324 nm

    Zero-dispersion slope

     0.092 ps/(nm2.km)

     

    Chromatic dispersion

    @ 1288 to 1339 nm

    @ 1550 nm

    @ 1625 nm

     

    3.5 ps/(nm. km)

    18 ps/(nm. km)

    22 ps/(nm. km)

    PMD

    0.1 ps/km1/2

    Mode field diameter @ 1310 nm

    9.2±0.4μm

    Core / Cladding concentricity error

     0.5μm

    Cladding diameter

    125.0  0.7μm

    Cladding non-circularity

    1.0%

    Primary coating diameter

    245  10μm

    Proof test level

    ‌100 kpsi (=0.69 Gpa), 1%

     

  5. Performance of Optical Fiber Cable

    • Load: 1200N

    • Length of cable under load: 50 m

    • load time: ≥1min.

    • Loss change  0.1 dB @1550 nm

    • Fiber strain 0.33%

    • No fiber break and no sheath damage.

    • Loss change  0.1 dB @1550 nm

    • No fiber break and no sheath damage.

    • Points of impact: 3

    • Impact energy: 4.5 N.m

    • Loss change  0.1 dB @1550 nm

    • No fiber break and no sheath damage.

    • Bending radius: 20 x Cable diameter

    • Load: 50 N

    • No. of cycle: 25

    • Loss change  0.1 dB @1550 nm

    • No fiber break and no sheath damage.

    • Length: 1 m

    • Load: 50 N

    • Twist angle: ±180°

    • No. of cycle: 10

    • Loss change  0.1 dB @1550 nm

    • No fiber break and no sheath damage.

    • Temperature step:

    • Time per each step: 12 hrs

    • Number of cycle: 2

    • Loss change  0.05 dB/km@1550 nm

    • No fiber break and no sheath damage.

    1. Cable bending radius: 15 x Cable diameter (Static)

      25 x Cable diameter (Dynamic)

    2. Application temperature range

       

      Operating temperature range : -10oC to +70oC Storage / Transport temperature range : -10oC to +70oC Installation temperature range : 0oC to +50oC

    3. Mechanical & environmental performance test

      No.

      Items

      Test Method

      Acceptance Condition

       

      1

      Tensile Strength IEC 60794-1-2-E1



      2

      Crush Test

      IEC 60794-1-2-E3

      - Load: 1,000 N/100 mm

      - Load time: ≥1min.


       

      3

      Impact Resistance IEC 60794-1-2-E4

      -Times of per point: 1


       

      4

      Repeated Bending IEC 60794-1-2-E6



       

      5

       

      Torsion

      IEC 60794-1-2-E7



       

      6

       

      Temperature Cycling Test IEC 60794-1-2-F1

      +20oC-10oC+70o+20oC


  6. Packing and Marking

    • Manufacturer brand;

    • Roll-direction arrow;

    • Cable outer end position indicating arrow;

    • The word “OPTICAL FIBER CABLE”;

    • Origin, The word “MADE IN CHINA”;

    • Caution plate indicating the correct method for loading, unloading and convey the cable;

    • Other customer information such as contract no., project no., and delivery destination. (if needed)

    • Product name;

    • Cable type and size;

    • Drum length in meters;

    • Gross / Net weight in kilograms;

    • Drum number;

    • Manufacturer's name;

    • Manufacturing year and month;

    • Other customer information such as contract no., project no., and delivery destination. (if needed)

    1. Cable drum

    2. Marking plate

    3. Each single cable length been wound on plywood drum.

    4. Standard drum length is 4,000m ±5%.

    5. Covered by plastic buffer sheet.

    6. Sealed by plywood battens.

    7. At least 1m of cable inner end should be reserved for testing.

       

    8. Packing

    9. Marking


Inquiry now